TUBE-SMK

Smoke exshaust ducted axial fan according to EN 12101-3

The fans of the TUBE-SMK line have been designed to be employed in all the plants where it is prescribed the necessity to guarantee the smoke extraction in environments as car parks, commercial centers, hospitals, theatres, museums, buildings etc. TUBE-SMK fans have been designed and manufactured according to the European Directive EN 12101-3 obtaining the certification from an authorized autonomous certification body. This line is suitable to work in continuous at the temperature of 40°C and in case of emergency (fire) at the temperature of: 200°C for 120 minutes (F200) 300°C for 60 minutes (F300) - per 120 minuti (F300/120) 400°C for 120 minutes (F400) This concept of double operation is exactly translated by the term “dual purpose” introduced in the specific by the EN 12101-3 norm.

Download

ELIC-SMK

Smoke exhaust ring axial fan according to EN 12101-3

The fans of the ELIC-SMK line have been designed to be employed in all the plants where it is prescribed the necessity to guarantee the smoke extraction in environments as car parks, commercial centers, hospitals, theatres, museums, buildings etc. ELIC-SMK fans have been designed and manufactured according to the European Directive EN 12101-3 obtaining the certification from an authorized autonomous certification body. This line is suitable to work in continuous at the temperature of 40°C and in case of emergency (fire) at the temperature of: 400°C for 120 minutes (F400) This concept of double operation is exactly translated by the term “dual purpose” introduced in the specific by the EN 12101-3 norm.

Download

TUBE-JET-SMK

Axial fan for parking system according to EN 12101-3

Impulse fans TUBE-JET-SMK are used in the forced ventilation of car parks, to remove the most common pollutions (ex. CO) and in case of emergency (fire) it activates to prevent and restrict the damages to people and objects: creating escape routes from toxic smokes, preventing the propagation in the adjacent zones etc. Impulse fan TUBE-JET-SMK has the main characteristic to be ductless, offering a series of advantages as: - remarkable saving in times and costs of installation. - saving in running costs, possibility to ventilate or extract only specific areas of the garage, where it is effectively required. - Ease of removal with consequent lower costs of maintenance or displacement of the plant. TUBE-JET-SMK have been designed and manufactured in accordance with the new European Directive EN 12101-3 obtaining the certification by an independent certification body. This line is suitable to S1 service (continuous operation) at the temperature of 40°C and S2 service in case of emergency (fire) at the temperature of: - 200°C for 120 minutes (F200) - 300°C for 60 minutes (F300) tested 300°C/120' - 400°C for 120 minutes (F400). The notion of double operation is exactly translated by the term “dual purpose” introduced in this case by the Directive EN 12101-3.

Download

OCT-JET-SMK

Compact axial fan for parking system according to EN 12101-3

Special feature of OCT-JET-SMK is their octagonal shape. The result of this is a great reductio n of the height compared to their homologous circular jet-fans TUBE-JET-SMK. They are therefore ideal in car parks application with very low ceilings.

Download

CENT-JET-SMK

Centrifugal fan for parking system according to EN 12101-3 (Tested 300°C/120')

Impulse fans CENT-JET-SMK are used in the forced ventilation of car parks, to remove the most common pollutions (ex. CO) and in case of emergency (fire), it activates to prevent and restrict the damages to people and objects: creating escape routes from toxic smokes, preventing the propagation in the adjacent zones etc. Impulse fan CENT-JET-SMK has the main characteristic to be ductless, offering a series of advantages as: - remarkable saving in times and costs of installation. - saving in running costs, possibility to ventilate or extract only specific areas of the garage, where it is effectively required. - Ease of removal with consequent lower costs of maintenance or displacement of the plant. CENT-JET-SMK have been designed and manufactured in accordance with the European Directive EN 12101-3 obtaining the certification by an independent certification body. This line is suitable to S1 service (continuous operation) at the temperature of 40°C and S2 service in case of emergency (fire) at the temperature of 300°C for 120 minutes (F300). The notion of double operation is exactly translated by the term “dual purpose” introduced in this case by the Directive EN 12101-3.

Download